Command ‘Save Current Values to Recipe’ΒΆ

Function: This command creates a new recipe definition in the recipe manager and stores the current values of the persistent variables in it. You should execute this command before the command Reorder list and clear gaps in order to avoid a possible loss of data. You can subsequently restore the data with the command Restore values from recipe.

Call: Main menu Deklarationen

Requirement: The application is in online mode and the persistence editor (persistent variable list) is active.

Note

If a list already exists in the recipe manager with the corresponding names when saving a persistent variable list, then the current persistent variables are sorted into the list:

  • New persistent variables are added to the list
  • Variables, that are not in the list, will be deleted

Therefore, it is possible to add more recipes to the list in the recipe manager and these will be retained . However, if new variables are added to the list, then these are deleted the next time the command Save Current Values to Recipe is executed.