Operators

CODESYS V3 supports all IEC-61131-3 operators. These operators are recognized implicitly throughout the project. In addition to these IEC operators, CODESYS also supports some non-IEC 61131-3 operators.

Operators are used in blocks, such as functions.

Note

For information about the processing order (binding strength) of the ST operators, please refer to the section on ST expressions.

Caution

For operations with floating-point data types, the computational result depends on the applied target system hardware.

Caution

For operations with overflow or underflow in the data type, the computational result depends on the applied target system hardware.

Overflow/underflow in the data type

The CODESYS compiler generates code for the target device and computes temporary results always with the native size that is defined by the target device. For example, computation is performed at least with 32-bit temporary values on x86 and ARM systems and always with 64-bit temporary values on x64 systems. This provides considerable advantages in the computation speed and often also produces the desired result. But this also means that an overflow or underflow in the data type is not truncated in some cases.

Examples

Example 1

The result of this addition is not truncated and the result in dwVar is 65536.

VAR
wVar : WORD;
dwVar: DWORD;
END_VAR

wVar := 65535;
dwVar := wVar + 1;

Example 2

The overflow and underflow in the data type is not truncated and the results (bVar1, bVar2) of both comparisons are FALSE on 32-bit and 64-bit hardware.

VAR
wVar1 : WORD;
wVar2 : WORD;
bVar1 : BOOL;
bVar2 : BOOL;
END_VAR

wVar1 := 65535;
wVar2 := 0;
bVar1 := (wVar1 + 1) = wVar2;
bVar2 := (wVar2 - 1) = wVar1;

Example 3

By the assignment to wVar3, the value is truncated to the target data type WORD and the result bvar1 is TRUE.

VAR
wVar1 : WORD;
wVar2 : WORD;
wVar3 : WORD;
bVar1 : BOOL;
END_VAR

wVar1 := 65535;
wVar2 := 0;
wVar3 := (wVar1 + 1);
bVar1 := wVar3 = wVar2;

Example 4

In order to force the compiler to truncate the temporary results, a conversion can be inserted.

The type conversion makes sure that both comparisons are 16-bit only and the results (bVar1, bVar2) of both comparisons are each TRUE.

VAR
wVar1 : WORD;
wVar2 : WORD;
bVar1 : BOOL;
bVar2 : BOOL;
END_VAR

wVar1 := 65535;
wVar2 := 0;
bVar1 := TO_WORD(wVar1 + 1) = wVar2;
bVar2 := TO_WORD(wVar2 - 1) = wVar1;

Comparison operators

A comparison operator is a Boolean that compares two inputs (first and second operand).

Operator ‘GT’

Operator ‘LT’

Operator ‘LE’

Operator ‘GE’

Operator ‘EQ’

Operator ‘NE’

Type conversion operators

You can explicitly call type conversion operators. The type conversion operators described below are available for typed conversions from one elementary type to another elementary type, as well as for overloading. Conversions from a larger type to a smaller type are also implicitly possible (for example, from INT to BYTE or from DINT to WORD).

Typed conversion: <elementary data type> _TO_ <another elementary data type>

Overloaded conversion: TO_ <elementary data type>

Elementary data types:

<elementary  data type> =
__UXINT | __XINT | __XWORD | BIT | BOOL | BYTE | DATE | DATE_AND_TIME | DINT | DT | DWORD | INT | LDATE | LDATE_AND_TIME | LDT | LINT | LREAL | LTIME | LTOD | LWORD | REAL | SINT | TIME | TOD | UDINT | UINT | ULINT | USINT | WORD

The keywords T, TIME_OF_DAY and DATE_AND_TIME are alternative forms for the data types TIME, TOD, and DT. T, TIME_OF_DAY and DATE_AND_TIME are not represented as a type conversion command.

Hint

If the operand value for a type conversion operator is outside of the value range of the target data type, then the result output depends on the processor type and is therefore undefined. This is the case, for example, when a negative operand value is converted from LREAL to the target data type UINT.

Information can be lost when converting from larger data types to smaller data types.

Hint

String manipulation when converting to STRING or WSTRING

When converting the type to STRING or WSTRING, the typed value is left-aligned as a character string and truncated if it is too long. Therefore, declare the return variable for the type conversion operators <>_TO_STRING and <>_TO_WSTRING long enough that the character string has enough space without any manipulation.

See also

Namespace operators

Namespace operators are extended from IEC 61131-3 operators and make it possible for you to provided unique access to variables and modules, even when you use the same name multiple times for variables or modules in a project.

Operator - Global Namespace

Operator - Namespace for Global Variables Lists

Operator - Enumeration Namespace

Operator - Library Namespace

Multicore operators

Working with different tasks requires the synchronization of these tasks. This is especially true when working on multicore platforms. Some special operators are provided in CODESYS to support this synchronization.

These operators are extensions of IEC-61131-3. The operators TEST_AND_SET and __COMPARE_AND_SWAP are used for similar tasks.

Operator ‘TEST_AND_SET’

Operator ‘__COMPARE_AND_SWAP

Operator ‘__XADD’